Base Preparation Guide

You can use the information below as a guidance to plan for your pad preparation.

Preferred Base Material

  • Fine Crusher Dust
  • Screened Sand (do NOT use recycled sand as it may contain contaminants)
  • Screened Sand is NOT suitable for RT-310 and RT-365

Compaction

Minimum of 120kPa

Levelling

The Pad must be LEVEL to +/- 10mm

Site Access

  • Please ensure adequate access to the site for a small
    truck or 4WD and trailer, bearing in mind soil and
    weather conditions.

  • Vehicle access is to be available to within 10 metres
    of site.
water tank base crusher dust

Reference Table

MODEL

MINIMUM PAD DIAMETER

MINIMUM PAD THICKNESS REQUIRED m3 OF SAND/CRUSHER DUST REQUIRED m 3 BLUE METAL (20mm) EXCLUSION ZONE
REQUIRED AROUND
TANK BASE
RT-25 5.5m 150mm 3.5m 3 0.8m 3
RT-40 6.5m 150mm 4.5m 3 0.8m 3
RT-60 7.5m 150mm 6.0m 3 1.0m 3
RT-80 8.5m 150mm 8.0m 3 1.0m 3
RT-100 9.5m 150mm 10.0m 3 1.2m 3
RT-130 10.5m 150mm 13.0m 3 1.2m 3
RT-160 11.5m 150mm 16.0m 3 1.6m 3
RT-200 12.5m 150mm 19.0m 3 1.6m 3
RT-230 13.5m 150mm 22.0m 3 2.0m 3
RT-275 14.5m 150mm 25.0m 3 2.1m 3
RT-310 14.0m 250mm

27.0m3

Do NOT use sand

2.0m 3
RT-365 15.0m 250mm

47.0m3

Do NOT use sand

2.1m 3